Chromatography Liquid Chromatography (LC) Gas Chromatography (GC) Thin-layer Chromatography(TLC)
Spectrometer AAS ICP Raman Spectrometer FT-IR Spectrometer UV-Vis Spectrophotometer Terahertz Spectrometer Infrared Spectrometer Terahertz Imager Spectroscopy Consumables Others
Mass Spectrometer MALDI-TOF-MS GC-MS ICP-MS
Physical Property Analysis Instrument Differential Scanning Calorimeter Melting Point Apparatus Refractometer Polarimeter Viscometer Density Meter
Sample Preparation Laboratory Water Purification System Evaporator Extractor Centrifuge Mixer Pipette Digester Others
Life Science Safety Cabinet Freezer PCR Microplate Reader Incubator Others
Elemental Analysis Kjeldahl Apparatus TOC Analyzer Carbon&Sulphur Analyzer Metal Analyzer Others
Lab Consumables Biochemical Consumables SPE Cartridges QuEChERS Kits
PPE Instruments Oxygen Concentrator Sterilizer
Environmental Measurement Iinstruments Gas Measurement Device
Others Magnetic Content Analyzer Glassware Washer Capping Machine Freeze Dryer Burette PH Meter Calorimeter Titrator Nitrogen Generator Automatic Drop Point and Softening Point Tester
Measurement range | 0.1%~100% |
Sample weight | 0.5g~3g |
Repeatability error | Craw Fiber Content below 10%, ≤0.4% Craw Fiber Content above 10%, ≤1% |
Capacity | 6 pcs/batch |
Pre-heating time | 10-12min |
Heating to boiling | 13-15min |
Display | 7 inches touch color screen |
Rated power | 2.2KW |
Power supply | 220 VAC ±10% 50Hz |
Dimension | 776mm×476mm×644mm |
F800 Fiber Analyzer is with advanced design, easy operation and flexible application. It can be used in the conventional Weende method to analyze crude fiber and Van Soest analysis to wash the fiber. Applies to plant, feed, food and other agricultural products as well as the determination crude fiber, neutral detergent fiber (NDF), acid detergent fiber (ADF), hemicellulose and acid detergent lignin (ADL).
Technology Advantage
Hidden solution barrel pull structure designed to facilitate dosing operation, provides the safest fiber analysis.
The corrosive liquid is not in contact with any pump body, to avoid waste discharge pump susceptible to corrosion phenomena.
The crucible recoil function is designed to prevent sample in the crucible can not caking filtration.
With dosing overflow protection function,to prevent dosing corrosive liquid overflow due to operator error, protect the safety of the operator.
Adjust the crucible heating power in time, enabling customers to control the heating rate easily and low down the energy consumption, ECO-friendly.
Having a built-in pre-heating function, greatly reduces the whole experi-ment time.
Provide five various specifications crucible specifications to meet the needs of different samples for standard configuration.
Can detect crude fiber, neutral detergent fiber (NDF), acid detergent fiber (ADF), hemicellulose and acid detergent lignin (ADL).