Chromatography Liquid Chromatography (LC) Gas Chromatography (GC) Thin-layer Chromatography(TLC)
Spectrometer AAS ICP Raman Spectrometer FT-IR Spectrometer UV-Vis Spectrophotometer Terahertz Spectrometer Infrared Spectrometer Terahertz Imager Spectroscopy Consumables Others
Mass Spectrometer MALDI-TOF-MS GC-MS ICP-MS
Physical Property Analysis Instrument Differential Scanning Calorimeter Melting Point Apparatus Refractometer Polarimeter Viscometer Density Meter
Sample Preparation Laboratory Water Purification System Evaporator Extractor Centrifuge Mixer Pipette Digester Others
Life Science Safety Cabinet Freezer PCR Microplate Reader Incubator Others
Elemental Analysis Kjeldahl Apparatus TOC Analyzer Carbon&Sulphur Analyzer Metal Analyzer Others
Lab Consumables Biochemical Consumables SPE Cartridges QuEChERS Kits
PPE Instruments Oxygen Concentrator Sterilizer
Environmental Measurement Iinstruments Gas Measurement Device
Others Magnetic Content Analyzer Glassware Washer Capping Machine Freeze Dryer Burette PH Meter Calorimeter Titrator Nitrogen Generator Automatic Drop Point and Softening Point Tester
Q-6012 Aerosol photometer is used to test whether there is leakage on HEPA filter. According to the principle of light scattering, it is portable, yet rugged for in-situ filtration system integrity testing.
The instrument conforms to NSF49 /1 EST / ISO14644-3, could realize rapid detection of upstream and downstream concentration detection and real-time display leakage on the host and handheld device, and could find leaking position rapidly and accurately.
Standards
GMP Factory and device
ISO14644-3:2005 Cleanrooms and associated controlled environments—Part 3:Test methods GB 50591-2010 Code for construction and acceptance of cleanroom
YY0569-2005 Biosafety cabinet
NSF49-2002 Biosafety cabinet
Features
Powerful function:
Stable digital photometer
Good human-computer interaction:
5.0 -inch color screen , touch operation;
Lightweight, portable and equipped with suitcase, easy to carry;
The handheld device is equipped for hard to reach areas, easy to control, display and sample;
Built-in battery ((optional) >3.5H;
Data query:
USB & Printer available for real-time reporting;
Audit Tracing & assign permissions to users, further guarantee data integrity;
Sampling data can be imported to PC;
Automatic reminder:
When exceed the set value, light & voice alarm;
Inform you to replace the high efficiency filter;
Sampling flowrate | 28.3L/min ±2.5% |
Dynamic Range | (0.0001 〜700) Hg/L |
Leakage detection | 0.0001% 〜100% |
Sensitivity | 1% of readings > 0.01% to 100% |
Repeatability | 0.5% of readings > 0.01% to 100% |
Data storage | 100000 groups |
Environment temperature | (10-35) °C |
Environment humidity | 5%-85% (No condensations No icing) |
Storage requirements | (-10-40) °C No condensation when relative humidity lower than 85%. |